1.4. COMBUSTION AIR SUPPLY
It is mandatory to connect this stove to an outside
combustion air source to reduce the risk of hopper
burn back caused by negative pressure. An
insulated 4” inside diameter metallic pipe, either
flexible or rigid, must be attached to the inlet at the
stove’s rear (refer to figure 5). A rodent guard
(minimum ¼” wire mesh) must be used at the
terminus (refer to figure 7). All connections must be
secured and airtight by either using the
appropriately sized hose clamp and/or UL-181-AP
foil tape. Also make sure that the fresh air damper
is open while the stove is running. The fresh air
intake damper is located at the back of the stove
right hand side (refer to figure 6.).
For mobile home installations only:
No combustion air supply may exceed 10 feet.
Sources of Outside Combustion Air:
A hole in floor near stove rear terminating only
in a ventilated crawl space.
A hole in the wall behind the stove.
FIGURE 6.
The fresh air intake damper
FIGURE 5
Rear view