Enerzone Solution 2.0 Specifications

Browse online or download Specifications for Stoves Enerzone Solution 2.0. Enerzone Solution 2.0 Specifications [en] User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
45285
ENERZONE WOOD STOVE MANUAL
MODEL SOLUTION 3.4
US ENVIRONMENTAL
PROTECTION AGENCY
PHASE II CERTIFIED
WOOD STOVE
STOVE BUILDER INTERNATIONAL
INC..
1700, Leon-Harmel, Quebec City
(Quebec), Canada G1N 4R9
Tel : (418) 527-3060
Fax : (418) 527-4311
www.enerzone-intl.com
Verified and tested following
ULC S627 and UL 1482
Standards
by:
READ AND KEEP THIS MANUAL FOR REFERENCE
Page view 0
1 2 3 4 5 6 ... 39 40

Summary of Contents

Page 1 - MODEL SOLUTION 3.4

45285 ENERZONE WOOD STOVE MANUAL MODEL SOLUTION 3.4 US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED WOOD STOVE STOVE BUILDER INTER

Page 2

9 Graphic 1 A- Clearance to combustible material with no protection. B- 500 mm (20 po.) minimum; C- 25 mm (1 po.) minimum; D- Between 25 mm

Page 3 - TABLE OF CONTENTS

10 Graphic 2 A- 25 mm (1 po.) minimum; 1- Combustible wall ; 2- Non-combustible spacer; 3- 0.61 mm (0.024") sheet metal. Graphic 3 A- 25 m

Page 4

11 Graphic 5 A- 25 mm (1 po.) minimum; 1- Combustible wall; 2- Non-combustible spacer; 3- Brick. Graphic 6 A- 25 mm (1 po.) minimum; 1- Com

Page 5 - SECTION 1.0 - INSTALLATION

121.4 FLOOR PROTECTOR If the stove is to be installed on top of a combustible floor, it must be guarded by a non-combustible material extending at l

Page 6

13SECTION 2.0 CHIMNEY (FLUE SYSTEM) 2.1 DEFINITIONS For clarity, the following definitions should be used with respect to these instructions: •

Page 7 - 1.3 CLEARANCES

14USA the ANSI NFPA 70 and ANSI NFPA 211 installation codes are to be followed. If you are using a masonry chimney, it is important that it be built

Page 8

15 FIGURE 2.2 Minimum Height of the Chimney 2.2.1 Step by step installation of your factory-built chimney The way to install your chimney may v

Page 9 - Shielding

16Stove pipe • An adequate number of stove pipe sections. • A 90o elbow FIGURE 2.2.1 (A) Typical installation through the wall

Page 10 - Graphic 1

17Typical installation through the ceiling Ceiling support system If your chimney must rise inside the house and go through the ceiling, you need t

Page 11 - Graphic 2

18 2.2.2 Typical installation through an existing masonry chimney You can also install your stove using your existing masonry chimney. To do so, f

Page 12

1INTRODUCTION Stove Builder International, one of the most important wood stove and fireplace manufacturers in North America, congratulates you on y

Page 13 - FIGURE 1.4 Floor protector

19 FIGURE 2.2.2 (B) Factory Built Thimble

Page 14

20 FIGURE 2.2.2 (C) Brick Thimble

Page 15

212.3 CHIMNEY CONNECTOR Your chimney connector (commonly called stove pipe) and chimney must have the same diameter as the stove’s exhaust outlet. T

Page 16

22 FIGURE 2.3 (A) Connecting Sections 1/4" RISE PER FOOT FIGURE 2.3 (B) Minimum Slope

Page 17

23Avoid 90 degree eblows We recommend that you use two 45 degree elbows instead

Page 18

242.4 DRAFT Your E.P.A Enerzone stove’s performance will be optimised if it is installed with a chimney (flue) system that provides an adequate dra

Page 19

252.6 THE ADVANTAGE OF USING A BLOWER (FAN) A blower is installed at the back of your E.P.A Enerzone stove model Solution 3.4. The blower should b

Page 20

26SECTION 3.0 OPERATION Keep these instructions for future reference. WARNING: • ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED I

Page 21

273.1 SAFETY INFORMATION • These stoves are designed for safe operation WHEN BURNING WOOD ONLY. Altering or modifying the unit or installation w

Page 22 - 2.3 CHIMNEY CONNECTOR

28• Although the ceramic glass is extremely durable under any normal use, a few precautions are required. Do not attempt to push logs further into t

Page 23 - 1/4" RISE PER FOOT

2TABLE OF CONTENTS 1.1 GENERAL INSTALLATION ...

Page 24 - Avoid 90 degree eblows

29 Wood species Energy yield (millions of BTU/cord) High energy yield Oak 29 Sugar Maple 28 Beech 26 Yellow birch 25 Ash 24 Elm 23 Medium energy y

Page 25 - 2.5 OUTSIDE COMBUSTION AIR

303.2.2 Simple wood moisture test Add one large piece of wood to the top of an established fire. If it starts to burn on three sides within one mi

Page 26

31Intensity Draft Setting Low Push Control completely to end of travel toward the left. Medium Low Pull Control to the right by 3/8” from closed p

Page 27 - SECTION 3.0 OPERATION

32long enough to achieve a hot fire. The wood should be placed with air in between individual pieces. Use a poker to make an air channel in the embe

Page 28 - 3.1 SAFETY INFORMATION

33 SECTION 4.0 MAINTENANCE 4.1 CLEANING AND PAINTING YOUR STOVE Clean the stove frequently so that soot, ash, and creosote do not accumulate. Do

Page 29 - 3.2 FUEL

34 Glass specifications: Robax 5mm with dimensions of 17 3/32" x 9 13/16" DOOR FRAMEGLASS RETAINERGLASSGLASSFRAMEDOOROVERLAY

Page 30

35• Push the ashes through the hole and leave an ash bed of approximately 1” deep on the firebox bottom to help maintain a hot ember bed. • Clear

Page 31 - 3.4 LIGHTING A FIRE

364.6 BAFFLE INSTALLATION 4.6.1 Baffle installation and brick layout for Solution 3.4 model All firebrick and ceramic wool baffles must be pr

Page 32 - 3.5 MAINTAINING THE FIRE

374.7 SECONDARY AIR TUBE REPLACEMENT (see Figure 4.11) Figure 4.7.1 – Secondary air tube replacement

Page 33 - 3.6 FAN (BLOWER) OPERATION

38 SECTION 5.0 SPECIFICATIONS 5.1 SOLUTION 3.4 Fuel Type Cordwood Test Standards ULC S627 (CSA B366.2) & UL 1482 residential.

Page 34 - SECTION 4.0 MAINTENANCE

3SECTION 5.0 SPECIFICATIONS ... 38 5.1 SOLUT

Page 35 - IN A COMBUSTIBLE CONTAINER

39ENERZONE LIMITED LIFETIME WARRANTY The warranty of the manufacturer extends only to the original consumer purchaser and is not transferable. This

Page 36 - 4.5 CHIMNEY (FLUE) CLEANING

4SECTION 1.0 - INSTALLATION When installed and operated as described in these instructions, the E.P.A Enerzone wood stove is suitable for use as a

Page 37 - 4.6 BAFFLE INSTALLATION

51.1.1 Installation of the decorative u-shaped inserts Your freestanding Enerzone wood stove is equipped with decorative u-shaped inserts. See tabl

Page 38

6 1.2 POSITIONING THE STOVE It is very important to position the wood stove in an area that will favour the most efficient heat distribution throu

Page 39 - SECTION 5.0 SPECIFICATIONS

7 Figure 1.3 Clearances to combustible materials

Page 40

81.3.1 Reduced clearances You may decrease the clearances by installing heat radiation shields between the walls or the ceiling and the stove. Th

Comments to this Manuals

No comments